MDX BRAID
Platinum Cured Braid Reinforced Medical Grade Silicone Hose



* Values listed are typical and are meant only as a guide to aid in design. Field testing should be performed to find the actual values for your application.




Sold by standard length only (25 ft.).

*Burst pressures can be expected to decrease by at least 20% for each 200 ° F increase up to 350 ° F.

- Medical & Dental Equipment       
- Pharmaceutical Processing        
- Laboratory Uses                  
- Insulation Sleeving                 
- Thermal Protection                
- Computers                    
- Appliances                       
- Food Handling                   
- Beverage & Dairy Service          
- Duplicating Equipment            
- Gaskets. Seals & 0-Rings
- Hot Fill & Vacuum Systems
- Stirring Vessels

- Fermenter Lines
- Liquid Resin Feeds
- Viscous Material Handling
- Peristaltic Pumps
- Adhesive Line
- Sterile Bottle Filing
- Surgical Drains
- I.V. Administration
- Blood & Biological Fluid Handling
- Dialysis
- Clean Rooms
- Cell Culturing
- Vaccine Transfer

- Silicone elastomer meets USP class VI requirements
- Manufactured under Good Manufacturing Practices (GMP) in a controlled   environment
- Platinum cured for the highest degree of purity (least extractables)
- Open mesh polyester braiding incorporat­ed within the walls of offers   increased pressure   capabilities
- Non-reactive to body tissues and fluids
- Reusable - will withstand repeated sterilization

The construction of platinum-cured MDX BRAID consists of a core of silicone elastomer, an open polyester braid reinforcing layer, and a covering of silicone elastomer. The braid reinforcement allows for increased pressure usage over unreinforced silicone tubing.

MDX BRAID hose surface properties resist encrustation, and will not support bacteria growth. The hose is pliable and contains no plasticizers.

Radiopaque hose can be supplied with the Barium Sulfate opaquing agent, either fully dispersed throughout the hose, co-extruded as striping on the outer surface, or fully encapsulated within the wall. If exposed to repeated steam sterilization or long-term high temperature or pressure, silicone will eventually become gummy and should be replaced.

Note: MDX BRAID is not recommended for implant or in-body uses. Care is recommended in the selection and application of fittings and clamps. Sharp, barbed fittings or unlined metal clamps could tear into the hose wall and cause possible failure.

The Excelon Tube Snip Cutter easily makes clean, smooth cuts and works well with Silbrade Medical silicone hose. Also available, Excelon Tube Snip Cutter Replacement Blades (Parts No: RF38000)

Email sales@sps-canada.com
Tel 519-756-7946          
Fax 519-756-1395           









PVC Tubing



 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   CONTACT  US     COMPANY  POLICY

© Copyright 2006
Sanitary Process Solutions
All Rights Reserved.